Wednesday, February 22, 2012
 English (United States) English (Canada)

 

 

Firebox Boilers

 

Efficient MF three-pass design, available in 10 horse power to 300 horse power models.  Our Firebox boilers are fitted with a forced draft flame retention burner that results in an efficiency of over 80%. This boiler-burner combination gives reliable operation with minimum maintenance.
 
Design:
 
·         Efficient 3-Pass firebox design incorporating the wetback principal
·         Oil fired burner standard but can be modified for other fuel sources
·         ASME code constructed and stamped for 15 psi steam/30 water
·         Our boilers can be custom built to ASME code for higher pressures if desired
·         Conforms to interprovincial regulations
·         All welded construction is used throughout
·         Steel channels form the base of the boiler
·         Steel skids and lifting eyes
·         Large firebox volume insures quiet operation through the complete cycle
·         Large furnace volume for ultimate combustion efficiency
·         Insulated with 2 inches of mineral wool
·         Jacket is 16 gauge sheet metal finished with a hard finish enamel
·         Easy access to fireside surfaces
·         Ample waterside cleanout openings
·         Fully automatic operation
·         UL listed forced draft burners
·         UL listed controls and trim
·         Factory test fired
·         Flame observation ports, front and rear
 
 
Burner:
 
·         The complete burner is listed with CSA and Underwriter’s Laboratories
·         Forced draft type, factory assembled, wired and tested
·         Equipment includes direct driven blower that supplies combustion air and forces products of combustion through the boiler and stack
·         Totally enclosed hinged, 14 gauge electrical control cabinet, containing a combustion safeguard control system, motor starter(s), control circuit transformer to 115 volts
·         Manual on-off switch, numbered terminal strips, flame observation port, control fuse and internal access
·         Upon interruption of electrical power, the burner will recycle before fuel valve opens
·         Upon flame failure, the electronic combustion control shall lockout and require manual reset
·         Burner motor will not run during lockout condition
 
 
Installation:
 
·         Bring the electrical supply to the control panel
·         Hook up oil, steam and return lines
  
Stack:
 
·         Through pressurized firing, only a stub stack is required to carry off the products of combustion
 
 
Steam boiler fittings:
 
·         Includes safety valve, steam gauge, siphon cock and drain, gauge glasses complete with rods, low water cutoff and pump control, pressure controls and tube cleaner
 
Water boiler fittings:
 
·         Equipped with relief valve, temperature/pressure gauge, high/low operating controls, low water cutoff and tube cleaner

 

 

Firebox Boiler Certifications

  

All of our Firebox Boilers are manufactured to the following certifications:
 

 

American Society of Mechanical Engineers

Underwriters Laboratories

 

We have been making Firebox boilers for over one hundred and fifty years to the standards of the day for schools, churches, factories and institutions.  Our boilers are reliable and efficient and we have a long history of satisfied customers.

If you have a requirement for a dependable heating system, call us (902.752.2521) contact us or request a quote today.  We will be pleased to respond to your request.

 

 

Copyright I Matheson 2009